Sleet ERP + IoT
Sleet ERP + IoT: connect your machines
Sleet ERP takes data straight from your shop floor. Machines, PLCs, sensors, weighing scales and energy meters send their counts, run time, weights and readings to the ERP, so production, stock and quality records fill in without a shift-end register.
- Machine API, PLC or IoT gateway
- Modbus, OPC UA and MQTT
- Set up machine by machine
Can an ERP connect to shop-floor machines?
Yes. Sleet ERP connects to a machine in one of three ways: through the machine’s own API, through a PLC or IoT gateway fitted next to it, or over a standard industrial protocol such as Modbus, OPC UA or MQTT. The gateway reads the signal, such as a part count, a run or stop state, a weight or a meter reading, and sends it to Sleet ERP over your network. The ERP then matches it to the machine, the work order and the item.
- Machines with a controllerRead over the controller’s network port or its API.
- PLC and SCADA linesA gateway reads the tags you choose from the PLC or the SCADA system.
- Older machinesA simple sensor on the machine gives the count or the run and stop signal.
What you can do with it
Eight uses for machine data in the ERP.
Start with one or two and add the rest later. Which of these you switch on depends on the signals your machines can give, and we go through that with you in the demo.
Live production count
Each cycle or piece is counted at the machine and shown against the work order’s target, so the supervisor sees the shortfall during the shift and not the next morning.
Downtime tracking
The run and stop signal shows when a machine stopped and for how long. The operator or supervisor adds the reason, such as no material, changeover or breakdown.
OEE by machine and shift
Availability, performance and quality worked out from machine run time, the count and the rejects, in place of a hand-filled sheet.
Stock posted from the scale
A weight from a weighing scale or weighbridge can go straight onto a goods receipt, a production entry or a dispatch, so the stock figure is the weighed figure.
Quality readings
Temperature, pressure, weight or dimension readings recorded against the batch or work order, and checked against the limits you set.
Energy per batch
Units from an energy meter recorded per machine, shift or batch, so power can be seen as part of the cost of making an item.
Preventive maintenance alerts
Running hours or cycle counts from the machine raise a maintenance reminder when a service is due, in place of a calendar date that ignores how hard the machine ran.
Batch traceability
The machine, the time and the readings stay with the batch record, so a customer complaint can be traced back to the run it came from.
What can be connected
From a new CNC machine to an old power press.
A machine does not have to be new or “smart”. It has to give a signal that a gateway can read. These are the usual routes, described by type and not by brand.
| Type of equipment | How it connects | What you get |
|---|---|---|
| Machines with a controllerCNC machines, moulding machines, packaging lines | The controller’s Ethernet port or the machine’s API, usually over OPC UA or Modbus TCP | Count, cycle time, run and stop state, alarms |
| PLC and SCADA linesProcess lines, conveyors, filling and batching plants | A gateway reads the chosen tags from the PLC, or from the SCADA system above it | Counts, states, process values |
| Older machines without a controllerPower presses, looms, lathes, older moulding machines | A sensor is fitted: a proximity or photo sensor for the count, a current sensor for running or stopped | Count, run and stop state |
| Weighing scales and weighbridgesPlatform scales, bench scales, weighbridges | The serial (RS-232 or RS-485) or Ethernet output of the weight indicator | Stable weight, with the unit |
| Energy metersPanel meters on a machine, line or feeder | Modbus over RS-485 or Ethernet | Units (kWh), load, power factor |
| Counters and process sensorsPiece counters, temperature, pressure, flow and level sensors | Digital or analog (4–20 mA) inputs on the gateway | Counts and readings at the interval you choose |
Tell us the make and model of each machine and what it can output. We check it before you buy any hardware. Share your machine list
Data flow
From a pulse at the machine to a record in the ERP.
The same five steps apply whether the source is a PLC tag, a scale or a sensor.
- 1
The machine gives a signal
A count pulse, a state, a weight or a meter reading, from the controller, the PLC or a fitted sensor.
- 2
The gateway reads it
It reads the signal over Modbus, OPC UA or a wired input, and adds the machine’s identity and the time.
- 3
It is sent to Sleet ERP
Over your internet connection, through an encrypted link, using the API or MQTT. If the link drops, a gateway with local storage holds the readings and sends them later.
- 4
The ERP matches it
The reading is matched to the machine, the work order running on it and the item being made.
- 5
The record is updated
Output, downtime, stock, quality readings or meter units are updated, and the people who need to know are alerted.
Signal to record
What each signal becomes in the ERP.
A raw machine signal means little by itself. The useful part is the record it fills in.
| Signal from the machine | Record in Sleet ERP | What you see |
|---|---|---|
| Piece or cycle count | Output on the work order | Produced quantity against the target, by machine and shift |
| Run and stop state | Downtime entry for the machine | Stop time and reasons, by machine and shift |
| Weight from a scale | Goods receipt, production entry or dispatch | Stock moves at the weighed quantity |
| Temperature, pressure, dimension | Reading on a quality check | Out-of-limit readings are flagged |
| Energy units (kWh) | Energy use per machine, shift or batch | Power seen next to output |
| Running hours or cycles | Maintenance reminder | Service is called when the machine has done the work |
OEE
OEE from the machine’s own data.
OEE (overall equipment effectiveness) shows how much of the planned production time a machine spent making good pieces at its expected speed. It is three ratios multiplied together.
- Availability = run time ÷ planned production time
- Performance = actual output ÷ output expected at the ideal cycle time
- Quality = good pieces ÷ total pieces
Filled in by hand, these numbers arrive late and miss the short stops. When the count and the run and stop time come from the machine, and rejects are entered against the work order, the three ratios can be worked out for each machine and shift.
What you need
Three things on your side.
Most plants already have the first one and part of the third.
A network at the machine
Wired LAN, Wi-Fi or a mobile data SIM where the gateway sits. The gateway only needs to reach the internet outwards; nothing has to be opened to the outside.
A gateway, where the machine has no API
A small industrial device in the panel or beside the machine that reads the signals and passes them on. One gateway can often serve several machines that are close together.
A list of machine signals
For each machine: what it can output (PLC tags, a count pulse, a serial port) and what you want from it. Your machine supplier or automation contractor usually has this.
Also useful to have ready
- Machines or work centres set up in Sleet ERP
- Items and work orders, so a count has something to post against
- One person on your side who owns the rollout
- Your electrician or automation contractor for the wiring
Implementation
Start with one machine, then roll out.
A pilot on one machine or one line shows what the data looks like before you commit the whole plant.
- 01
Machine list
You share the machines, their make and model, and what you want to measure on each.
- 02
Connection plan
For each machine we agree the route: its API, a gateway on the PLC, or a fitted sensor.
- 03
Pilot
One machine or one line is connected and its signals are mapped to work orders, stock or quality checks.
- 04
Check the numbers
For a few shifts the machine figures are compared with the manual register, and differences are sorted out.
- 05
Roll out
The remaining machines are added in batches, and dashboards and alerts are set for each role.
- 06
Hand over
Supervisors and operators are shown the screens they will use and how to add a stop reason.
Before and after
The shift register against the machine’s own count.
| Written by hand | With machines connected | |
|---|---|---|
| Production count | Written at the end of the shift and typed in the next day | Counted at the machine and posted during the shift |
| Downtime | Estimated from memory, short stops are missed | Every stop is timed; the reason is added by the operator |
| Stock from weighing | Weight read from the display and typed by hand | Weight taken from the scale onto the document |
| Quality readings | Noted on a paper check sheet | Stored against the batch and checked against limits |
| Maintenance | By calendar date | By running hours or cycles |
Industries
Where connected machines pay back first.
Any plant with repeating cycles, weighed material or metered utilities. A few examples of what is usually measured:
Plastics and moulding
Shots, cycle time, cavities, rejects and material weight per machine.
Packaging and printing
Running metres or sheets, speed, stops and changeover time.
Metal fabrication and machining
Parts per shift, spindle running time, idle time and tool-change stops.
Textiles
Loom or machine running time, picks or metres, and stops per shift.
Food and beverage
Batch weights, filling counts, and temperature readings for the batch record.
Chemicals and pharma
Batch weights, process temperature and pressure, and utility use per batch.
Auto and engineering components
Stroke or cycle counts, rejects, and die or tool life by cycles.
Building materials
Weighbridge weights in and out, batch counts and kiln or press running hours.
India and worldwide
Built for Indian factories, usable anywhere.
Sleet ERP is made in India by Airwix Technologies and runs in the browser, so a plant in India, the UAE, the UK or the US connects in the same way. Modbus, OPC UA (IEC 62541) and MQTT (an OASIS standard, also ISO/IEC 20922) are international standards, which is why the same approach works on machines bought from any country.
- 01
Mixed shop floors
New and old machines from different makers can sit on the same dashboard.
- 02
Several plants
Each plant has its own gateways; the ERP shows them together or plant by plant.
- 03
Your own fields
Add the fields your process needs to the documents the readings land on.
Questions
IoT and machine integration, answered.
Something else? Message us on WhatsApp at +91 82001 72869 or write to sales@getsleet.cloud.
Can Sleet ERP connect to any machine?
It can connect to any machine that gives a readable signal. That means a machine with its own API or network port, a machine run by a PLC, or an older machine fitted with a simple sensor for the count or the run and stop state. Share the make and model and we confirm the route before you buy anything.
Which protocols does the integration use?
On the shop-floor side, gateways commonly read machines over Modbus (RTU or TCP) and OPC UA, or over plain digital and analog inputs. From the gateway to Sleet ERP, data is sent through the ERP’s API or over MQTT. These are open industry standards, not tied to one maker.
Our machines are old and have no PLC. Can they still be connected?
Usually yes. A proximity or photo sensor can count strokes or pieces, and a current sensor can tell whether the machine is running. Those signals go to a gateway, which sends the count and the run and stop time to the ERP.
Do we need an IoT gateway?
Only where the machine cannot send data over the network by itself. A machine or line system with its own API can connect directly. PLCs, serial devices such as weighing scales and energy meters, and fitted sensors need a gateway to read them and pass the data on.
Can a weighing scale or weighbridge post weight to the ERP?
Yes, if the weight indicator has a serial (RS-232 or RS-485) or Ethernet output, which most industrial indicators have. The stable weight is read and placed on the document, such as a goods receipt, a production entry or a dispatch, so nobody types it.
What is OEE, and can it be worked out from machine data?
OEE (overall equipment effectiveness) is availability × performance × quality. Availability is run time divided by planned production time, performance is actual output against the output expected at the ideal cycle time, and quality is good pieces divided by total pieces. Once the count, the run and stop time and the rejects come from the machine, OEE can be worked out per machine and shift.
What happens when the internet or the factory network goes down?
The machines keep running as before. A gateway with local storage keeps the readings and sends them when the link returns, so counts are not lost. We recommend choosing a gateway with this store-and-forward feature.
Can the ERP control or stop our machines?
No. The integration reads data from the machine. It does not write settings to a PLC or start and stop equipment, so the machine’s own controls and safety systems stay as they are.
Does this replace our SCADA or MES?
No. SCADA controls and shows the process second by second. The ERP uses a small part of that data, such as counts, states, weights and batch readings, for production, stock, quality and costing records. If you already have SCADA, it is often the easiest place to read the data from.
How long does it take, and what does it cost?
It depends on how many machines you have, how old they are and what signals they give, so we quote after seeing your machine list. A pilot on one machine or line is the usual first step. Book a demo or talk to sales and share your machine list. Book a demo →
Does it work for factories outside India?
Yes. Sleet ERP runs in the browser and the protocols used are international standards, so a plant in the UAE, the UK, the US or elsewhere is connected in the same way.
Sleet ERP
What the machine data connects to.
Show us your machine list.
Book a demo and tell us what runs on your shop floor. We will show you how each machine can be connected to Sleet ERP and what you would see on screen.
Explore more
